D80 GC Generator Set

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Get a Quote
Minimum Rating 80 ekW
Maximum Rating 80 ekW
Emissions/Fuel Strategy U.S. EPA Cert., Tier 3
Voltage 208 to 600 Volts
Frequency 60 Hz
Speed 1800 rpm
Duty Cycle Standby
Engine Model C4.4, In-line 4, 4-cycle diesel
Bore 4.1 in
Stroke 5 in
Displacement 269 in³
Compression Ratio 16.7:1
Aspiration Turbocharged
Fuel System Common Rail
Governor Type Mechanical, ADEM™A4
Length - Maximum 82.6 in
Width - Maximum 43.3 in
Height - Maximum 52.9 in
Dry Weight - Genset (maximum) 950 lb
Air Inlet System
  • Air cleaner; light duty with disposable element
  • Air Cleaner
Cooling System
  • Radiator and cooling fan with guards
  • Fan drive, battery charging alternator drive
  • Caterpillar extended life coolant
  • Coolant drain line with valve
Control Panel
  • GCCP 1.2 Control panel
Exhaust System
  • Stub pipe, gaskets, raincap and SAE exhaust flange for customer use - shipped loose
Fuel System
  • Standard open set fuel tank / base supplied base, formed steel with single wall integral 24-hour fuel tank
Generator
  • Circuit breaker, IEC, 3 pole, mounted in tower panel
  • Voltage regulator (single phase sensing)
  • IP23 protection
  • Segregated low voltage (AC/DC) wiring panel
  • 12 Leads
  • Tower panel, IP22, bottom cable entry
Governing System
  • Mechanical and electrical governing system - model dependent
Lube System
  • Lubricating oil
  • Oil drain line with valve
Mounting System
  • Includes lifting provision and drag points
  • Termination points for coolant and lube oil drain lines
  • Captive linear vibration isolators between base and engine-generator
Starting/Charging System
  • Batteries
  • 24V battery with rack and cables
General
  • Engine and alternator pre-paint, Caterpillar yellow
Alternator System
  • 3 Phase sensing
  • Anti-condensation heater
  • R frame auxilliary winding
  • Permanent magnet
Circuit Breakers
  • Circuit Breaker Upgrades - 4 Pole circuit reaker to 250A, 400A and 630 A
Cooling System
  • Low coolant level shutdown
  • Coolant heater
  • Low coolant temp alarm
Control Panel Options
  • Earth fault (2 wire only)
  • Overload shutdown via breaker
  • Earth leakage (2 wire only)
  • Volt free contacts
  • Panel mounted audible alarm
  • Battery charger
  • GCCP 1.2 control panel
  • Control panel heater
  • Voltage adjust potentiometer
  • Emergency stop with key
  • Speed adjust potentiometer
Enclosures
  • Sound attenuated Level 2 enclosure
Fuel System
  • High fuel level alarm
  • Open set narrow base
  • Low fuel level alarm
  • Bunded fuel tank
  • Low fuel level shutdown
  • Compact skidbase for open set
  • Skidbase for CALG enclosure sets
Global Certifications
  • Certification for CIS
Mounting Options
  • Battery removal
  • Industrial silencer
  • Electronic governor
  • External single point lift - enclosure
  • Silencer installation kit
Special Packing/Inspectons for Shipment
  • PGS test report @ 1.0 power factor
  • PGS test report @ 0.8 power factor
General - Accessories / Miscellaneous
  • Stone guards / rad trans flange
  • Packing case - canopied set
  • Packing case - compact set