C2.2 Generator Set

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Get a Quote
Minimum Rating 15.5 ekW
Maximum Rating 20.0 ekW
Emissions/Fuel Strategy R96/EUIIIa Equivalent
Voltage 110 to 415 Volts
Frequency 60 Hz
Speed 1800 rpm
Duty Cycle Standby, Prime
Engine Model Cat® C2.2, In-line 4, 4-cycle diesel
Bore 3.3 in
Stroke 3.9 in
Displacement 135.2 in³
Compression Ratio 22.5:1
Aspiration Naturally Aspirated
Fuel System Indirect Injection
Governor Type Mechanical
Length - Maximum 59.1 in
Width - Maximum 24.4 in
Height - Maximum 43.9 in
Air Inlet System
  • Air cleaner; light duty with disposable element
Control Panel
  • GCCP 1.3
Cooling System
  • Radiator and cooling fan with guards
  • Fan drive, battery charging alternator drive
  • Caterpillar extended life coolant
  • Coolant drain line with valve
Exhaust System
  • Stub pipe, gaskets, raincap & SAE exhaust flange for customer use; shipped loose
Fuel System
  • Standard open set fuel tank / base supplied
  • Base, formed steel with single wall integral 8-hour fuel tank
Generators and Generator Attachments
  • IP23 Protection
  • Circuit breaker, IEC, 3 pole, mounted in tower panel
  • 12 Leads
  • Segregated low voltage (AC/DC) wiring panel
  • Voltage regulator (single phase sensing)
  • Tower panel, IP22, bottom cable entry
Governing System
  • Mechancial governing system
Lube System
  • Oil drain line with valve
  • Lubricating oil
Mounting System
  • Captive linear vibration isolators between base and engine-generator
  • Includes lifting provisions and termination points for coolant
Starting / Charging System
  • 12 Volt battery with rack and cables
General
  • Engine and alternator pre-paint, Caterpillar yellow
Alternator Options
  • Coastal insulation protection
Certificates
  • Global certification for CIS
  • European upgrade to STD set for CE certificate
Circuit Breakers
  • 4 Pole circuit breaker
  • Pad-lockable breaker device
Control Panel Options
  • Volt free contacts for common alarm
  • Battery charger
  • Volt free contacts for genset running
  • Emergency stop with key
  • GCCP 1.3
Cooling System
  • Coolant heater
Enclosures
  • Single point lift for enclosure
  • Sound attenuated enclosure (GALV)
Fuel System
  • Skidbase for enclosures
  • Skidbase for open sets
  • 1000 Hr extended service interval
  • DEFRA bunded fuel tank
  • Fuel transfer control
  • Base feet
  • Low fuel level alarm
Mounting Options
  • Silencer installation kit
  • Industrial silencer removal
  • Battery removal
Special Test and Inspection
  • PGS test report @ 1.0 power factor
General
  • Packing case - compact set
  • Radiator stone guard
  • Packing case - canopied set